測(cè)量范圍 |
600.0mV/6.000/60.00/600.0V (輸入阻抗10MΩ) |
精度 |
±1.0%rdg±3dgt |
交流電壓
AC V |
測(cè)量范圍 |
6.000/60.00/600.0V (輸入阻抗10MΩ) |
精度 |
±1.5%rdg±5dgt (45 ~ 400Hz) |
直流電流
DC A |
測(cè)量范圍 |
60.00/120.0A |
精度 |
±2.0%rdg±8dgt (60A) ±2.0%rdg±5dgt (120A) |
交流電流
AC A |
測(cè)量范圍 |
60.00/120.0A |
精度 |
±2.0%rdg±5dgt (45 ~ 65Hz) |
|
測(cè)量范圍 |
600.0Ω/6.000/60.00/600.0kΩ/6.000/60.00MΩ |
精度 |
±1.0%rdg±5dgt (600Ω/6/60/600kΩ) ±2.0%rdg±5dgt (6MΩ) ±3.0%rdg±5dgt (60MΩ) |
導(dǎo)通蜂鳴 |
低于35±25Ω時(shí) |
二極管測(cè)試 |
2V ±3.0%rdg±5dgt 開(kāi)路電壓: 2.7V |
電容測(cè)試
|
測(cè)量范圍 |
400.0nF/4.000/40.00µF |
精度 |
±2.5%rdg±10dgt |
|
(AC A) |
100/1000Hz/10kHz ±0.2%rdg±2dgt (100Hz)
±0.1%rdg±1dgt (1000Hz/10kHz) |
|
100/1000Hz/10/100/300.0kHz ±0.2%rdg±2dgt (100Hz) ±0.1%rdg±1dgt (1000Hz/10/100/300.0kHz) |
|
(Input sensitivity Current: more than 2A Voltage: more than 2V [~10kHz]/more than 20V [10k~300kHz]) |
被測(cè)導(dǎo)體尺寸 |
Ø12mm max. |
耐壓 |
3540V AC for 5 minute |
適用安全標(biāo)準(zhǔn) |
IEC 61010-1 CAT.III 300V, CAT.II 600V Pollution degree 2 IEC 61010-031,
IEC 61010-2-032,
IEC 61326 |
電源 |
R03 (1.5V) × 2
Continuous measuring time: DCV: approx. 150hours, ACA: approx. 25hours (Auto power save: approx. 15 minutes) |
尺寸 |
128 (L) × 92 (W) × 27 (D) mm |
重量 |
220g approx. (含電池) |
附件 |
R03 (1.5V) × 2,
使用說(shuō)明書 |
可選件 |
9107 (軟質(zhì)盒]) |